KRAL Flowmeters OMH Series.
For high pressures with highest accuracy.
With high pressure to an accurate measuring result.
The KRAL flow meters OMH series were especially designed to handle high pressures of up to 420 bar that can occur in the field of mechanical engineering, at test benches and in hydraulic applications.
Large flow ranges usually require large pipe cross sections and are therefore bulky flow metering devices. Due to the compact measuring element, the OMH series fits into a small housing and offers the significant advantage of being compact and lightweight in this pressure class, even for high flow rates.
The pressure resistance is provided by a very rigid housing, maintaining the compact dimensions, and at the same time the proven precision of the KRAL flow meters, even at extreme pressure levels.
- Technical data.
Technical data OMH-013 OMH-020 OMH-032 OMH-052 OMH-068 OMH-0100 Nominal diameter DN [inch] 1/2 3/4 1 1 1/2 2 4 Total length with threaded flange G [mm] 150 185 255 320 385 500 Weight with threaded flange G [Kg] 7 12 29 55 81 150 Flow rate I/h Qmax 900 2,700 9,000 31,500 63,000 180,000 Qnom 600 1,800 6,000 21,000 42,000 120,000 Qmin 6 18 60 210 420 1,200 Flow rate I/min Qmax 15 45 150 525 1,050 3,000 Qnom 10 30 100 350 700 2,000 Qmin 0.1 0.3 1.0 3.5 7.0 20 Max. pressure [bar] 420 420 420 420 420 250 Temperature [°C] -20 to +200 -20 to +200 -20 to +200 -20 to +200 -20 to +200 -20 to +200 Viscosity [mm²/s] 1 to 1x106 1 to 1x106 1 to 1x106 1 to 1x106 1 to 1x106 1 to 1x106 Precision of measurement value ±0.1 % ±0.1 % ±0.1 % ±0.1 % ±0.1 % ±0.1 % Repeatability ±0.01 % ±0.01 % ±0.01 % ±0.01 % ±0.01 % ±0.01 % K-factor K2 [P/I] 2,432 1,280 468 142 79.6 33.6 K3 [P/I] 7,296 2,560 1,014 302 167 57.6 K4 [P/I] 7,296 2,560 1,014 302 167 87.6 Frequency f2 at Qnom [Hz] 405 640 780 828 929 1,120 f3 at Qnom [Hz] 1,216 1,280 1,690 1,760 1,949 1,920 f4 at Qnom [Hz] 1,216 1,280 1,690 1,762 1,948 2,920 - Sensor.
Sensor BEG 06 / BEG 06A* BEG 44A BEG 45 with BEV 13 BEG 53A / BEG 54A* Application Ex-range High pressures, broad temperature range High pressures, broad temperature range Flow direction detection K-factor K1 K2 K3 K4 Signal Namur Push-Pull PNP Push-Pull Temperature [°C] -40 to +150 -40 to +150 -40 to +250 -40 to +125 Max. pressure [bar] 350 420 420 650 *dependent on nominal value - Operating instructions.